What's included
- Technical audit of the current system: consumption, condition and compliance
- Retrofit plan prioritized by criticality and estimated returns
- Replacement and modernization of components, controls and automation
- Compliance with current standards and refrigerants
- Results measurement: consumption before × after
When a retrofit makes sense
A retrofit modernizes a system that works but uses too much energy, fails often or relies on components and refrigerants that are leaving the market. Instead of replacing everything, the technical audit shows where the losses are: compressors and condensers outside ideal conditions, high condensing temperature, outdated controls.
The plan prioritizes stages by criticality and estimated return, with documented assumptions. After each stage, consumption is measured before and after to confirm the gain.
How it works
-
System and energy bill audit
-
Retrofit plan with estimated gain and ROI per stage
-
Staged execution, planned with your operation
-
Measurement: consumption and performance before × after
Who it is for
- Systems over 10 years old or with rising consumption
- Operations out of compliance or using phased-out refrigerants
- Teams that want to cut energy cost without replacing the whole system
FAQ
Do you only service Smart Cold equipment?
No. We service equipment from any manufacturer. For Smart Cold equipment, we are the only factory-authorized service provider.
Do I need to stop my operation for a retrofit?
Some sections of the system may need to be shut down. Work is planned with your operation, using quieter periods or a phased approach. Whether shutdowns are needed, and how long they last, is determined after the technical assessment.
How do I know if a retrofit pays off?
The technical audit answers that with numbers: estimated gain and ROI per stage. If it doesn't pay off, the report says so, you decide with data.
How long does a retrofit take to pay back?
It depends on the system, current consumption and the stages chosen. The plan includes the estimated return for each stage, with documented assumptions, and before-and-after measurement confirms the result.
Can you retrofit equipment from another brand?
Yes. Retrofit is multi-brand and starts from an audit of the installed system, whatever the manufacturer.
My system uses R-22. Do I need to replace it?
R-22 is being phased out in Brazil under the country’s commitment to the Montreal Protocol, and it tends to become more expensive and harder to find. The audit assesses the system and points to the path: conversion to a current refrigerant or a staged replacement.
Let's assess modernisation
Tell us the city and state, current issues and, if known, the system's age and capacity.
- 24/7 emergency service
- In-house engineering in the field
- Over 15 years in operation
- Smart Cold authorized service provider